The Curlin 6000 CMS ™ is an easy-to-use, flexible and reliable multi-therapy ambulatory pump that features innovative Information on Demand (IOD) capabilities that allow quick and … Error code in CMS Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.Tek-Tips Posting Policies Jobs Jobs from Indeed What: Where: jobs by Link To This Forum! Already a member? When I fixed 100 Mbps FD on PBX site and on Sun using command:ndd -set /dev/bge0 adv_100fdx_cap 1ndd -set /dev/bge0 adv_100hdx_cap 0ndd -set /dev/bge0 adv_10fdx_cap 0ndd -set /dev/bge0 adv_10hdx_cap 0ndd -set http://allsoftwarereviews.com/cms-error/cms-error-code-322.php

Any idea why is this happening? This condition may be caused by an on-board fault or by faulty data received on one of the media module's external ports. Resources Join | Indeed Jobs | Advertise Copyright © 1998-2016 ENGINEERING.com, Inc. Error code in CMS is still 1400, but in Sun log /var/adm/messages there is no more errors.Any idea why is this happening? i thought about this

If Error Type 1538 is not present, then the media module has not been taken out-of-service, but it has generated 50% of the messages necessary to be considered hyperactive. However, if this error type is logged when the media module is being lightly used, it may indicate a problem with the media module or the equipment attached to it. Has anyone else had this problem where the error logs show what I would call an "unstable" connection and what did they do to remedy and stablize it? If all tests pass, run the Long Test Sequence.

Please try the request again. Close Reply To This Thread Posting in the Tek-Tips forums is a member-only feature. The Echo Canceller Memory Test, which is executed by firmware, failed. Join your peers on the Internet's largest technical computer professional community.It's easy to join and it's free.

Close Box Join Tek-Tips Today! RE: CMS Ethernet inteface problem kpearlt3 (TechnicalUser) 30 Nov 09 09:43 Can you post any errors you are getting on the PBX side of the configuration? If they are connected via a ethernet switch then this rule does not apply. http://www.saetechnologies.com/cms-error-code-1400/ If the same Aux Data value is logged more than once in a 24 hour period, the media module should be replaced. (g) Error Type 514 LAN External RAM Error.

The value in the Aux Data field indicates the type of hardware problem: Aux Data Problem 4352 External RAM failure 4353 Internal RAM failure 4355 Internal ROM failure If the board Refer to the appropriate test description and follow the recommended procedures. **If ports are assigned to the media module, then a minor alarm is raised. saetechnologies.com - Colorway Wordpress Theme by InkThemes.com

Skip to content. The system returned: (22) Invalid argument The remote host or network may be down.

Login HomeAboutIAUGAbout IAUGIAUG Board of DirectorsNewsContact UsJoinIAUGGeneral Membership InformationMembership BenefitsHow Engaged are IAUG Members?Join IAUGRenew Your IAUG MembershipUpdate Your Member ProfileIAUG365PublicationsEducationAvaya ENGAGE 2016 Session RecordingsEventsAvaya ENGAGE 2017Chapter MeetingsVirtual Events- WebinarsAvaya and https://support.avaya.com/public/index?page=content&id=SOLN295837&pmv=print&impressions=false Please try the request again. An alarm is raised if this error occurs three times within 10 minutes. If the board is not restored to normal operation, or the error recurs after the board was restored to normal operation, escalate the problem. (m) Error Types 3073 to 3160 Error

In attached file are file spi_err_1 and /var/adm/messages. check my blog Ross Mitchell [Sab] CMS Errors-1400 SPI Session Error: Data Collection is down October 28, 2006 08:05 PM (in response to Mary Wierbicki) Have you tried checking the spi session and spi Have you had any network issues or does you CMS connect directly to the phone system nfstroll . . [.] CMS Errors-1400 SPI Session Error: Data Collection is down November 5, Ross Mitchell [Sab] CMS Errors-1400 SPI Session Error: Data Collection is down November 5, 2009 12:33 PM (in response to Mary Wierbicki) Ancient thread indeed Have you checked your phone system

To clear the alarm and restore the board to the Packet Bus, use the commands busyout board GGGVS, reset board GGGVS, test board GGGVS long, release board GGGVS. Clear the alarm using the following commands: busyout board GGGVS, test board GGGVS long, release board GGGVS. The clan may be restarting. this content Try type release mis.

Post options. Your cache administrator is webmaster. Registration on or use of this site constitutes acceptance of our Privacy Policy.

Click Here to join Tek-Tips and talk with other members!

To resolve this problem, either remove the incorrect media module and insert the logically administered media module, OR use the change circuit-pack command to re-administer this slot to match the media The system returned: (22) Invalid argument The remote host or network may be down. A DS1 (DS1-MM, DS1-BD) differs from most media modules in that inserting the media module into the switch is not enough to make the board usable. this is what we have in /var/adm/messagesNov 24 00:20:04 0842TFI050 bge: [ID 801593 kern.notice] NOTICE: bge0: link down Nov 24 00:20:24 0842TFI050 bge: [ID 801593 kern.notice] NOTICE: bge0: link up 10Mbps

The auxiliary data identifies the following error events: Aux Data Event 4096 Bad major heading 4097 Bad port number 4098 Bad data 4099 Bad sub-qualifier 4100 State inconsistency 4101 Bad logical Add Stickiness To Your Site By Linking To This Professionally Managed Technical Forum.Just copy and paste the BBCode HTML Markdown MediaWiki reStructuredText code below into your site. Avaya: CM/Aura (Definity) Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. http://allsoftwarereviews.com/cms-error/cms-error-code-1902.php What I don't know is why it keeps going down.

When I set both site to autonegotiation, both sites were connected with 100 Mbps FullDuplex.This two boxes are directly connected with cable without any switch between.Ethernet link is now stable even Major alarms on this MO may be downgraded to minor or warning alarms based on values set in the set options command. (a) Error Type 1 Indicates that the media module If any of the ports on this media module are alarmed, refer to the repair procedures for those maintenance objects. I could not found any errors in /var/adm/messages for the time when error occurred in spi_err_1 log.Can some one help wit this?

Please try the request again. When no faults are detected for 20-30 minutes, the DS1-MM is restored to normal operation. If the problem persists, and there are no PKT-BUS alarms or port alarms, then replace the media module. (l) Error Type 1538 The hyperactive media module is out-of-service and may exhibit If the error occurs three times within 10 minutes, the board is isolated from the Packet Bus and the board alarmed.

Generated Sat, 19 Nov 2016 17:38:53 GMT by s_wx1196 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.9/ Connection RE: CMS Ethernet inteface problem kpearlt3 (TechnicalUser) 30 Nov 09 09:43. Following are Group Health's clean claim requirements for the professional claims form. evil_scooby mentionned spi session and spi error logs, where do I look that up?

This error occurs when there is a hardware fault in the PPE external RAM. Check your Exception Reports for Other/Data Collection events to see if you see errors like "link stalled". The alarm is raised after the media module has been missing for a period of 15 minutes. RE: CMS Ethernet inteface problem Smovk (IS/IT--Management) (OP) 2 Dec 09 19:30 I change the switch between PBX and CMS, so SUN server(CMS) and C-LAN are nowconnected with forced 100Mbps Fulduplex.Now